Background: Although stroke survivors can benefit from robotic gait rehabilitation, stationary robot-assisted gait training needs further investigation. In this paper, we investigated the efficacy of this approach (with an exoskeleton or an end-effector robot) in comparison to the conventional overground gait training in subacute stroke survivors. Methods: In a multicenter controlled clinical trial, 89 subacute stroke survivors conducted twenty sessions of robot-assisted gait training (Robotic Group) or overground gait training (Control Group) in addition to the standard daily therapy. The robotic training was performed with an exoskeleton (RobotEXO-group) or an end-effector (RobotEND-group). Clinical outcomes were assessed before (T0) and after (T1) the treatment. The walking speed during the 10-Meter Walk Test (10 MWT) was the primary outcome of this study, and secondary outcomes were the 6-Minute Walk Test (6 MWT), Timed Up and Go test (TUG), and the modified Barthel Index (mBI). Results: The main characteristics assessed in the Robotic and Control groups did not differ at baseline. A significant benefit was detected from the 10 MWT in the Robotic Group at the end of the study period (primary endpoint). A benefit was also observed from the following parameters: 6 MWT, TUG, and mBI. Moreover, patients belonging to the Robot Group outperformed the Control Group in gait speed, endurance, balance, and ADL. The RobotEND-group improved their walking speed more than the RobotEXO-group. Conclusion: The stationary robot-assisted training improved walking ability better than the conventional training in subacute stroke survivors. These results suggest that people with subacute stroke may benefit from Robot-Assisted training in potentiating gait speed and endurance. Our results also support that end-effector robots would be superior to exoskeleton robots for improving gait speed enhancement.

Robotic versus Conventional Overground Gait Training in Subacute Stroke Survivors: A Multicenter Controlled Clinical Trial

Tamburella, Federica;
2023-01-01

Abstract

Background: Although stroke survivors can benefit from robotic gait rehabilitation, stationary robot-assisted gait training needs further investigation. In this paper, we investigated the efficacy of this approach (with an exoskeleton or an end-effector robot) in comparison to the conventional overground gait training in subacute stroke survivors. Methods: In a multicenter controlled clinical trial, 89 subacute stroke survivors conducted twenty sessions of robot-assisted gait training (Robotic Group) or overground gait training (Control Group) in addition to the standard daily therapy. The robotic training was performed with an exoskeleton (RobotEXO-group) or an end-effector (RobotEND-group). Clinical outcomes were assessed before (T0) and after (T1) the treatment. The walking speed during the 10-Meter Walk Test (10 MWT) was the primary outcome of this study, and secondary outcomes were the 6-Minute Walk Test (6 MWT), Timed Up and Go test (TUG), and the modified Barthel Index (mBI). Results: The main characteristics assessed in the Robotic and Control groups did not differ at baseline. A significant benefit was detected from the 10 MWT in the Robotic Group at the end of the study period (primary endpoint). A benefit was also observed from the following parameters: 6 MWT, TUG, and mBI. Moreover, patients belonging to the Robot Group outperformed the Control Group in gait speed, endurance, balance, and ADL. The RobotEND-group improved their walking speed more than the RobotEXO-group. Conclusion: The stationary robot-assisted training improved walking ability better than the conventional training in subacute stroke survivors. These results suggest that people with subacute stroke may benefit from Robot-Assisted training in potentiating gait speed and endurance. Our results also support that end-effector robots would be superior to exoskeleton robots for improving gait speed enhancement.
2023
end-effector
exoskeleton
gait
rehabilitation
robotics
stroke
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14085/8821
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact