Cytotoxic antineoplastic drugs (ADs) pose occupational risk and therefore require safe handling practices. We created, optimised, and validated an innovative monitoring protocol for simultaneously assessing 21 ADs in the healthcare environment, and also proposed surface exposure levels (SELs) to facilitate the interpretation of monitoring results, as there are currently no occupational exposure limits for ADs. The environmental AD monitoring data were collected in nine Italian hospitals between 2008 and 2017 and include 74,565 measurements in 4,814 wipe samples. Excellent overall recovery and sensitivity of the analytical methods along with innovative desorption automation make this protocol useful for routine monitoring. AD contamination was found in 3,081 measurements, confirming potential exposure in healthcare workers. Samples taken at the beginning and the end of work shifts, allowed to calculate 75th and 90th percentile values for each ADs both in preparation and administration units and we created a traffic-light colour-coding system to facilitate interpretation of the findings. The introduction of SELs will provide a solid basis for improving occupational safety and focusing on contamination control.

A new approach to assessing occupational exposure to antineoplastic drugs in hospital environments

Dugheri S.
;
2018-01-01

Abstract

Cytotoxic antineoplastic drugs (ADs) pose occupational risk and therefore require safe handling practices. We created, optimised, and validated an innovative monitoring protocol for simultaneously assessing 21 ADs in the healthcare environment, and also proposed surface exposure levels (SELs) to facilitate the interpretation of monitoring results, as there are currently no occupational exposure limits for ADs. The environmental AD monitoring data were collected in nine Italian hospitals between 2008 and 2017 and include 74,565 measurements in 4,814 wipe samples. Excellent overall recovery and sensitivity of the analytical methods along with innovative desorption automation make this protocol useful for routine monitoring. AD contamination was found in 3,081 measurements, confirming potential exposure in healthcare workers. Samples taken at the beginning and the end of work shifts, allowed to calculate 75th and 90th percentile values for each ADs both in preparation and administration units and we created a traffic-light colour-coding system to facilitate interpretation of the findings. The introduction of SELs will provide a solid basis for improving occupational safety and focusing on contamination control.
2018
Inductively coupled plasma mass spectrometry
Liquid chromatography-mass spectrometry
Surface contamination
Wipe test
Workplace safety
Adult
Antineoplastic Agents
Environmental Monitoring
Equipment Contamination
Female
Hazardous Substances
Health Personnel
Hospitals
Humans
Italy
Male
Middle Aged
Occupational Exposure
Occupational Health
Risk Assessment
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14085/40979
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 26
social impact