Purpose: To assess the qualitative relationship between liquid biopsy and conventional tissue biopsy. As a secondary target, we evaluated the relationship between the liquid biopsy results and the T stage, N stage, M stage, and compared to grading. Methods: The Local Ethics Committee of the “Università degli Studi della Campania Luigi Vanvitelli”, with the internal resolution number 24997/2020 of 12.11.2020, approved this spontaneous prospective study. According to the approved protocol, patients with lung cancer who underwent Fine-Needle Aspiration Cytology (FNAC), CT-guided biopsy, and liquid biopsy were enrolled. A Yates chi-square test was employed to analyze differences in percentage values of categorical variables. A p-value < 0.05 was considered statistically significant. Data analysis was performed using the Matlab Statistic Toolbox (The MathWorks, Inc., Natick, MA, USA). Results: When a genetic mutation is present on the pathological examination, this was also detected on the liquid biopsy. ROS1 and PDL1 mutations were found in 2/29 patients, while EGFR Exon 21 was identified in a single patient. At liquid biopsy, 26 mutations were identified in the analyzed samples. The mutations with the highest prevalence rate in the study populations were: ALK (Ile1461Val), found in 28/29 patients (96.6%), EML4 (Lys398Arg), identified in 16/29 (55.2%) patients, ALK (Asp1529Glu), found in 14/29 (48.3%) patients, EGFR (Arg521Lys), found in 12/29 (41.4%) patients, ROS (Lys2228Gln), identified in 11/29 (37.9%) patients, ROS (Arg167Gln) and ROS (Ser2229Cys), identified in 10/29 (34.5%) patients, ALK (Lys1491Arg) and PIK3CA (Ile391Met), identified in 8/29 (27.6%) patients, ROS (Thr145Pro), identified in 6/29 (20.7%) patients, and ROS (Ser1109Leu), identified in 4/29 (13.8%) patients. No statistically significant differences can be ob-served in the mutation rate between the adenocarcinoma population and the squamous carcinoma population (p > 0.05, Yates chi-square test). Conclusions: We showed that, when a genetic mutation was detected in pathological examination, this was always detected by liquid biopsy, demonstrating a very high concordance rate of genomic testing between tissues and their corresponding mutations obtained by liquid biopsy, without cases of false-negative results. In addition, in our study, liquid biopsy highlighted 26 mutations, with the prevalence of ALK mutation in 96.6% of patients, sup-porting the idea that this approach could be an effective tool in cases with insufficient tumor tissue specimens or in cases where tissue specimens are not obtainable.

Preliminary Experience of Liquid Biopsy in Lung Cancer Compared to Conventional Assessment: Light and Shadows

Urraro F.;
2022-01-01

Abstract

Purpose: To assess the qualitative relationship between liquid biopsy and conventional tissue biopsy. As a secondary target, we evaluated the relationship between the liquid biopsy results and the T stage, N stage, M stage, and compared to grading. Methods: The Local Ethics Committee of the “Università degli Studi della Campania Luigi Vanvitelli”, with the internal resolution number 24997/2020 of 12.11.2020, approved this spontaneous prospective study. According to the approved protocol, patients with lung cancer who underwent Fine-Needle Aspiration Cytology (FNAC), CT-guided biopsy, and liquid biopsy were enrolled. A Yates chi-square test was employed to analyze differences in percentage values of categorical variables. A p-value < 0.05 was considered statistically significant. Data analysis was performed using the Matlab Statistic Toolbox (The MathWorks, Inc., Natick, MA, USA). Results: When a genetic mutation is present on the pathological examination, this was also detected on the liquid biopsy. ROS1 and PDL1 mutations were found in 2/29 patients, while EGFR Exon 21 was identified in a single patient. At liquid biopsy, 26 mutations were identified in the analyzed samples. The mutations with the highest prevalence rate in the study populations were: ALK (Ile1461Val), found in 28/29 patients (96.6%), EML4 (Lys398Arg), identified in 16/29 (55.2%) patients, ALK (Asp1529Glu), found in 14/29 (48.3%) patients, EGFR (Arg521Lys), found in 12/29 (41.4%) patients, ROS (Lys2228Gln), identified in 11/29 (37.9%) patients, ROS (Arg167Gln) and ROS (Ser2229Cys), identified in 10/29 (34.5%) patients, ALK (Lys1491Arg) and PIK3CA (Ile391Met), identified in 8/29 (27.6%) patients, ROS (Thr145Pro), identified in 6/29 (20.7%) patients, and ROS (Ser1109Leu), identified in 4/29 (13.8%) patients. No statistically significant differences can be ob-served in the mutation rate between the adenocarcinoma population and the squamous carcinoma population (p > 0.05, Yates chi-square test). Conclusions: We showed that, when a genetic mutation was detected in pathological examination, this was always detected by liquid biopsy, demonstrating a very high concordance rate of genomic testing between tissues and their corresponding mutations obtained by liquid biopsy, without cases of false-negative results. In addition, in our study, liquid biopsy highlighted 26 mutations, with the prevalence of ALK mutation in 96.6% of patients, sup-porting the idea that this approach could be an effective tool in cases with insufficient tumor tissue specimens or in cases where tissue specimens are not obtainable.
2022
conventional biopsy
liquid biopsy
lung cancer
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14085/40566
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact