Background: The use of articulating spacers, molded or prefabricated, becomes difficult in case of severe bone losses. Our idea was to customize the Molded Articulating Cement Spacers with cement stem extensions and if necessary metaphyseal cement augmentations in order to use them also in case of major bone defects. Methods: Fifty-four knees in fifty-three patients undergoing 2-stage exchange arthroplasty were divided in 4 groups, treated with 4 different types of spacers (Static, articulating molded, customized molded and metal on Poly) and evaluated in terms of Range of Motion (ROM), Knee Society Score (KSS), patients’ related outcome measures (PROMs), rate of complication and ease of the surgical exposure at the time of reimplantation. Results: At final follow-up, no statistical differences in terms of ROM and KSS were found between the articulating groups. Static Spacers showed statistically significant lower results both in terms of ROM and KSS comparing to the other 3 groups (P < 0.05). Considering PROMs, statistically better outcomes for all articulating spacers were found both when spacer was in place and at final follow-up comparing to the static spacers group (P < 0.05). No statistically significant difference was found between the 3 articulating spacers groups. Radiographic analysis did not show signs of loosening, migration or major bone loss. Conclusions: Customized Intraoperatively Molded Articulating Cement Spacers are a safe solution for two-stage revisions TKA with major bone defects and may provide a better quality of life for patients when in place comparing to static ones.

Customized intraoperatively molded articulating cement spacers for two-stage revisions TKA with major bone defects

Rossi S. M. P.;
2021-01-01

Abstract

Background: The use of articulating spacers, molded or prefabricated, becomes difficult in case of severe bone losses. Our idea was to customize the Molded Articulating Cement Spacers with cement stem extensions and if necessary metaphyseal cement augmentations in order to use them also in case of major bone defects. Methods: Fifty-four knees in fifty-three patients undergoing 2-stage exchange arthroplasty were divided in 4 groups, treated with 4 different types of spacers (Static, articulating molded, customized molded and metal on Poly) and evaluated in terms of Range of Motion (ROM), Knee Society Score (KSS), patients’ related outcome measures (PROMs), rate of complication and ease of the surgical exposure at the time of reimplantation. Results: At final follow-up, no statistical differences in terms of ROM and KSS were found between the articulating groups. Static Spacers showed statistically significant lower results both in terms of ROM and KSS comparing to the other 3 groups (P < 0.05). Considering PROMs, statistically better outcomes for all articulating spacers were found both when spacer was in place and at final follow-up comparing to the static spacers group (P < 0.05). No statistically significant difference was found between the 3 articulating spacers groups. Radiographic analysis did not show signs of loosening, migration or major bone loss. Conclusions: Customized Intraoperatively Molded Articulating Cement Spacers are a safe solution for two-stage revisions TKA with major bone defects and may provide a better quality of life for patients when in place comparing to static ones.
2021
Articulating
Bone loss
Infection
Spacer
Static
Two-stage revision
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14085/25741
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact