Purpose: To validate the ability of theranostic imaging biomarkers in assessing corneal cross-linking (CXL) efficacy in flattening the maximum keratometry (Kmax) index. Design: Prospective, randomized, multicenter, masked clinical trial (ClinicalTrails.gov identifier, NCT05457647). Participants: Fifty patients with progressive keratoconus. Intervention: Participants were stratified to undergo epithelium-off (25 eyes) and epithelium-on (25 eyes) CXL protocols using an ultraviolet A (UV-A) medical device with theranostic software. The device controlled UV-A light both for performing CXL and assessing the corneal riboflavin concentration (riboflavin score) and treatment effect (theranostic score). A 0.22% riboflavin formulation was applied onto the cornea for 15 minutes and 20 minutes in epithelium-off and epithelium-on protocols, respectively. All eyes underwent 9 minutes of UV-A irradiance at 10 mW/cm2. Main outcome measures: The primary outcome measure was validation of the combined use of theranostic imaging biomarkers through measurement of their accuracy (proportion of correctly classified eyes) and precision (positive predictive value) to classify eyes correctly and predict a Kmax flattening at 1 year after CXL. Other outcome measures included change in Kmax, endothelial cell density, uncorrected and corrected distance visual acuity, manifest spherical equivalent refraction and central corneal thickness 1 year after CXL. Results: Accuracy and precision of the theranostic imaging biomarkers in predicting eyes that had >0.1 diopter (D) of Kmax flattening at 1 year were 91% and 95%, respectively. The Kmax value significantly flattened by a median of -1.3 D (IQR, -2.11 to -0.49 D; P < 0.001); both the uncorrected and corrected distance visual acuity improved by a median of -0.1 logarithm of the minimum angle of resolution (logMAR; IQR, -0.3 to 0.0 logMAR [P < 0.001] and -0.2 to 0.0 logMAR [P < 0.001], respectively). No significant changes in endothelial cell density (P = 0.33) or central corneal thickness (P = 0.07) were noted 1 year after surgery. Conclusions: The study demonstrated the efficacy of integrating theranostics in a UV-A medical device for the precise and predictive treatment of keratoconus with epithelium-off and epithelium-on CXL protocols. Concentration of riboflavin and its UV-A light mediated photoactivation in the cornea are the primary factors determining CXL efficacy. Financial disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Assessment of the Predictive Ability of Theranostics for Corneal Cross-linking in Treating Keratoconus

Alunni Fegatelli, Danilo;
2024-01-01

Abstract

Purpose: To validate the ability of theranostic imaging biomarkers in assessing corneal cross-linking (CXL) efficacy in flattening the maximum keratometry (Kmax) index. Design: Prospective, randomized, multicenter, masked clinical trial (ClinicalTrails.gov identifier, NCT05457647). Participants: Fifty patients with progressive keratoconus. Intervention: Participants were stratified to undergo epithelium-off (25 eyes) and epithelium-on (25 eyes) CXL protocols using an ultraviolet A (UV-A) medical device with theranostic software. The device controlled UV-A light both for performing CXL and assessing the corneal riboflavin concentration (riboflavin score) and treatment effect (theranostic score). A 0.22% riboflavin formulation was applied onto the cornea for 15 minutes and 20 minutes in epithelium-off and epithelium-on protocols, respectively. All eyes underwent 9 minutes of UV-A irradiance at 10 mW/cm2. Main outcome measures: The primary outcome measure was validation of the combined use of theranostic imaging biomarkers through measurement of their accuracy (proportion of correctly classified eyes) and precision (positive predictive value) to classify eyes correctly and predict a Kmax flattening at 1 year after CXL. Other outcome measures included change in Kmax, endothelial cell density, uncorrected and corrected distance visual acuity, manifest spherical equivalent refraction and central corneal thickness 1 year after CXL. Results: Accuracy and precision of the theranostic imaging biomarkers in predicting eyes that had >0.1 diopter (D) of Kmax flattening at 1 year were 91% and 95%, respectively. The Kmax value significantly flattened by a median of -1.3 D (IQR, -2.11 to -0.49 D; P < 0.001); both the uncorrected and corrected distance visual acuity improved by a median of -0.1 logarithm of the minimum angle of resolution (logMAR; IQR, -0.3 to 0.0 logMAR [P < 0.001] and -0.2 to 0.0 logMAR [P < 0.001], respectively). No significant changes in endothelial cell density (P = 0.33) or central corneal thickness (P = 0.07) were noted 1 year after surgery. Conclusions: The study demonstrated the efficacy of integrating theranostics in a UV-A medical device for the precise and predictive treatment of keratoconus with epithelium-off and epithelium-on CXL protocols. Concentration of riboflavin and its UV-A light mediated photoactivation in the cornea are the primary factors determining CXL efficacy. Financial disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
2024
Corneal cross-linking
Keratoconus
Riboflavin
Theranostics
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14085/20796
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact